A study on stress distribution at the bone-implant interface in platform switched short dental implants by three-dimensional finite element model


1 Department of Preventive Dental Sciences, College of Dentistry, Gulf Medical University, Ajman, UAE
2 Departmeat of Periodontics, Rajah Muthiah Dental College and Hospital, Chidambaram, Tamil Nadu, India
3 Department of Restorative Dental Sciences, College of Dentistry, Gulf Medical University, Ajman, UAE

Correspondence Address:
Dr. Sesha Reddy Manchala
Department of Periodontics, College of Dentistry, Gulf Medical University, Ajman
UAE
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jdmimsu.jdmimsu_322_20

Rights and Permissions

Aims: The authors carried out this study to analyze the pattern of stress distribution in terms of eqicrestal and subcrestal implant placement at various depths using short platform switched dental implants. Settings and Design: Modeling of the mandibular posterior molar region done with uniformly thick 1.5 mm cortical bone with an inner core of cancellous bone by three-dimensional finite element model (FEM). Implant dimensions used in the study are of length 6 mm, diameter 4.6 mm, and 3.5 mm abutments. Subjects and Methods: The applied force was 100N in an axial and oblique direction (15°, 30°) for realistic simulation. All models created by ANSYS WORKBENCH.von Mises stress is evaluation in both cancellous and cortical bone at various depths. Translations interpreted on x, y, and z-axis with ten noded tetrahedron elements with 3° of freedom per node. Results: All five position of platform switched short osseointegrated implants analyzed by FEM simulations exhibited different stress-based biomechanical behavior, dependent on bone geometry, the direction of force applied as well as on the depth of implant placement. Conclusions: Oblique forces were more deleterious than axial forces. Subcrestal implant placement resulted in reduced stress in the cortical and cancellous bone.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed188    
    Printed24    
    Emailed0    
    PDF Downloaded20    
    Comments [Add]    

Recommend this journal