Morphometric measurement of fetal femur length for the prediction of gestational age in the IInd and IIIrd trimester of pregnancy by ultrasonography


Department of Anatomy, DMIMS (DU), Jawaharlal Nehru Medical College, Wardha, Maharashtra, India

Date of Web Publication2-Feb-2018

Correspondence Address:
Dr. Brij Raj Singh
Department of Anatomy, DMIMS (DU), Jawaharlal Nehru Medical College, Sawangi (M), Wardha, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jdmimsu.jdmimsu_71_17

Rights and Permissions
  Abstract 


Introduction: Femur length (FL) is a fetal biometric parameter used for estimation of gestational age. Gestational age determination by ultrasonography (USG) is very essential as it gives an accurate estimation. Aim and Objectives: This study is an attempt to measure FL of the fetus for the prediction of gestational age in the IInd and IIIrd trimester of pregnancy by USG. Materials and Methods: Five hundred pregnant women in the IInd and IIIrd trimester with the single live fetus and having no other complications either in mother or fetus, were selected for the study. Fetal FL was measured, and results were analyzed for accuracy in estimation of gestational age and were compared with findings of other workers. Observation and Results: Gestational age estimated from FL in 500 cases between 20 and 36 weeks of gestation showed that in the mean FL in each week of gestation the maximum difference of ±0.7 mm was found in the IInd trimester and ±2 mm was in the IIIrd trimester. The accuracy of the correctly diagnosed cases and P value decreases as pregnancy advance. Conclusion: Sonographic examination was found to be effective to assess the accurate FL parameter for different weeks of gestation. FL was found to be more appropriate in predicting gestational age in the IInd trimester and its reliability decreases in the IIIrd trimester.

Keywords: Femur length, morphometric study, ultrasonography


How to cite this article:
Roy M, Gajbe UL, Singh BR, Thute P. Morphometric measurement of fetal femur length for the prediction of gestational age in the IInd and IIIrd trimester of pregnancy by ultrasonography. J Datta Meghe Inst Med Sci Univ 2017;12:187-90

How to cite this URL:
Roy M, Gajbe UL, Singh BR, Thute P. Morphometric measurement of fetal femur length for the prediction of gestational age in the IInd and IIIrd trimester of pregnancy by ultrasonography. J Datta Meghe Inst Med Sci Univ [serial online] 2017 [cited 2019 Jul 16];12:187-90. Available from: http://www.journaldmims.com/text.asp?2017/12/3/187/224708




  Introduction Top


Morphometric analyses are performed to record the parameters of fetal anatomical features as well as to describe the developmental changes and are useful in planning appropriate care for the fetus, especially when dealing with growth restricted or large for date babies.[1] Fetal femur length (FL) can be used in estimating gestational age and as a screening device for the detection of congenital anomalies. Articles have shown that ultrasonographic measurement of FL is not only an accurate indicator of gestational age but also it has a stronger correlation with gestational age.[2],[3],[4]

An average normal gestational age, which is the length of the pregnancy, is approximately 40 weeks, with a normal range of 38–42 weeks. Reliable estimation of gestational age is essential as it allows appropriate scheduling of a woman's antenatal care, informs obstetric management decisions and facilitates the correct interpretation of fetal growth assessment.[5] Abnormal fetal growth patterns such as growth restriction or macrosomia may be missed or diagnosed incorrectly if gestational age is unknown or incorrect. The lack of accurate gestational age estimation means that preterm delivery and small-for-gestational-age rates are mere approximations in many parts of the world.[6]

In the II nd and III rd trimester of pregnancy, the fetus has grown sufficiently in size so that anatomic details are clearly identified, visualized, and measured. Optimal imaging can be difficult in some clinical situations, such as in a late pregnancy abnormal lie when the head is deep in the maternal pelvis or maternal obesity.[7]

Aim and objectives

The aim of the present study is to measure FL of the fetus for the prediction of gestational age in the II nd and III rd trimester of pregnancy by ultrasonography (USG).

The objectives of the present study are:

  1. To study the role of USG for estimation of gestational age
  2. To estimate the gestational age by USG measurement of FL.



  Materials and Methods Top


This study was carried out in the Department of Anatomy and in the Department of Radiodiagnosis, Acharya Vinoba Bhave rural hospital, Sawangi (Meghe), Wardha, Maharashtra, India. All the patients were referred from the Department of Obstetrics and Gynaecology.

Materials required are

  1. USG machine (Wipro GE, Logiq – P5 PRO)
  2. Transducers (Convex, Linear, TVS), Ultrasonic jelly
  3. A comfortable bed for the patient. Bed sheets to maintain the dignity of the patient.


This study consisted of 500 pregnant females of the II nd and III rd trimester, between 20 and 36 weeks of gestation.

Inclusion criteria

  1. The normal healthy pregnant females, between 20 and 36 weeks of gestation attending the Ante Natal Clinic in the department of Radiodiagnosis, Acharya Vinoba Bhave rural hospital, Sawangi (Meghe), Wardha for routine checkup were taken as subjects
  2. The last menstrual period of the patient with previous sonography report
  3. Pregnancy with single and viable fetus.


Exclusion criteria

  1. Pregnancy complicated by medical disorders such as anemia, diabetes mellitus, etc. in mother and congenital disorders of the fetus were excluded from the study
  2. Twin pregnancy were excluded from the study.


Method

Ultrasonographic examination comprised of recording the FL.

All examinations were performed by using a Grayscale real-time machine (Wipro GE, Logiq– P5 PRO USG MACHINE) employing a 3.5 MHz convex transducer [Figure 1].
Figure 1: Wipro GE logiq P5 pro ultrasonography machine with transducer

Click here to view


For the measurement of FL the transducer was placed at right angle to the fetal spine and passed down the fetus, maintain this angle to the caudal end because the distal femur was visualized. A clear image of the femur was obtained, the freeze frame was employed and with the help of multidirectional electronic calipers the FL was measured [Figure 2].
Figure 2: Ultrasonographic measurement of femur length

Click here to view


After noting the FL the complete information was recorded in the pro forma. Each parameter recorded was compared with its respective standard and analyzed statistically.


  Observation and Results Top


[Table 1] shows the comparison of the present study values of FL measurement with Western Nomogram (chart formulated by Hadlock 1984). We noted the maximum difference of ±0.7 mm in the II nd and ±2 mm in III rd trimester (the maximum difference of ±2 mm was found in 36 week) [Graph 1].
Table 1: Comparison of femur length measurement with western nomogram

Click here to view



Statistical analysis was performed by using descriptive and inferential statistics using Pearson's correlation coefficient, sensitivity and specificity and software used in the analysis were SPSS 22.0 version (SPSS Inc., IL, Chicago) and GraphPad Prism 6.0 version (GraphPad Software, CA 92037 USA) and P < 0.05 is considered as the level of significance.


  Discussion Top


In the present study, we have recorded FL of the fetus for assessment of gestational age.

In the present study, the specificity of FL value from known gestational age ranging 20–23 weeks was found 65%, and correlation coefficient was found to be 0.994 and P = 0.006, which was statistically significant. From 24 to 27 weeks accuracy was 52% and the correlation coefficient was 0.988 and P = 0.012, which was statistically significant. From 28 to 31 weeks, accuracy was again 52% and the correlation coefficient was 0.927 and P = 0.074, which was statistically insignificant. From 32 to 36 weeks accuracy was 24%, and the correlation coefficient was 0.995 and P = 0.0001, which was statistically significant. This study shows the accuracy of the correctly diagnosed cases and P value decreases as pregnancy advance.

In the present study, the mean FL in each week of gestation was compared with the western nomogram Jeanty et al.[8] in [Table 1]. The maximum difference of ± 0.7 mm was found in the II nd trimester and ± 2 mm was in the III rd trimester.

Hoeler and Quetel [9] analyzed over 300 fetuses, and they reported the variability during this period to be higher and that is ±3–3.5 weeks.

O'Brien and Queenan [10] proposed a new method for the prediction of gestational age in early II nd trimester by ultrasound measurement of FL. A growth curve of the calcified section of the femur was constructed which indicated that gestational age could be predicted with 95% confidence limits to ±6 days.

Hadlock et al.[11] studied the relationship between FL and gestational age by using cross-sectional analysis of 338 normal fetuses between 12 and 40 weeks. The prediction of gestational age from FL showed variability of ±9.5 days between 12 and 23 weeks. Beyond 23 weeks variability increased up to ±22 days.

Yeh et al.[12] studied 145 uncomplicated gravid patients with 16–42 weeks of gestation. The result of the analysis showed the variability in the estimation of gestational age by FL, between 25 and 35 weeks of gestation was <5 days. Beyond 35 weeks measurement of FL was less precised with more variability. The correlation coefficient of gestational age versus fetal FL was statistically greater than that of the gestation age versus fetal biparietal diameter.

In another study of 900 fetuses by Honarvar and Allahyari [13] there is a variability of ±5 days during 23–40 weeks of gestation.

Gupta et al.[14] conducted a study on 512 cases and they found the variability of ±8 days in the estimation of gestational age by using FL.

In this study, the results are similar to above-mentioned studies, where the accuracy of the correctly diagnosed cases and P value decreases as pregnancy advance.


  Conclusion Top


The conclusions derived from the present study are:

  • The sonographic examination is found to be effective to assess the fetal well-being and growth
  • The accuracy of the FL parameter for different weeks of gestation indicated that the correctly diagnosed gestational age by sonographic measurement is not equally homologous with gestational age by known menstrual date
  • The specificity and sensitivity of FL were found to be more appropriate in predicting gestational age in the II nd trimester, and its reliability decreases in the III rd trimester. Mean value of FL parameter was found to have minimum discrepancy for the prediction of gestational age.


Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Nash P. Amniotic fluid index. Neonatal Netw 2013;32:46-9.  Back to cited text no. 1
[PUBMED]    
2.
Wolfson RN, Peisner DB, Chok LL. Comparison of biparietal diameter and femur length in the third trimester. Effect of gestational age and variation in fetal growth. J Ultrasound Med 1986;4:139.  Back to cited text no. 2
    
3.
Woo JS, Wan CW, Fang A, Au KL, Tang LC, Ghosh A, et al. Is fetal femur length a better indicator of gestational age in the growth-retarded fetus as compared with biparietal diameter? J Ultrasound Med 1985;4:139-42.  Back to cited text no. 3
    
4.
Raman S, Teoh T, Nagaraj S. Growth patterns of the humeral and femur length in a multiethnic population. Int J Gynaecol Obstet 1996;54:143-7.  Back to cited text no. 4
[PUBMED]    
5.
Dubil EA, Magann EF. Amniotic fluid as a vital sign for fetal wellbeing. Australas J Ultrasound Med 2013;16:62-70.  Back to cited text no. 5
[PUBMED]    
6.
Nabhan AF, Abdelmoula YA. Amniotic fluid index versus single deepest vertical pocket as a screening test for preventing adverse pregnancy outcome. Cochrane Database Syst Rev 2008;(3):CD006593.  Back to cited text no. 6
    
7.
Hamza A, Herr D, Solomayer EF, Meyberg-Solomayer G. Polyhydramnios: Causes, diagnosis and therapy. Geburtshilfe Frauenheilkd 2013;73:1241-6.  Back to cited text no. 7
[PUBMED]    
8.
Jeanty P, Rodesch F, Delbeke D, Dumont JE. Estimation of gestational age from measurements of fetal long bones. J Ultrasound Med 1984;3:75-9.  Back to cited text no. 8
[PUBMED]    
9.
Hoeler EW, Quetel TA. The relationship between fetal femur length and biparietal diameter in last half of pregnancy. Am J Obstet Gynaecol 1981;141:759-62.  Back to cited text no. 9
    
10.
O'Brien GD, Queenan JT. Growth of the ultrasound fetal femur length during normal pregnancy. Part I. Am J Obstet Gynecol 1981;141:833-7.  Back to cited text no. 10
    
11.
Hadlock FP, Harrist RB, Deter RL, Park SK. Ultrasonically measured fetal femur length as a predictor of menstrual age. Am J Roentgenal 1982;138:875.  Back to cited text no. 11
    
12.
Yeh MN, Bracero L, Reilly KB, Murtha L, Aboulafia M, Barron BA, et al. Ultrasonic measurement of the femur length as an index of fetal gestational age. Am J Obstet Gynecol 1982;144:519-22.  Back to cited text no. 12
    
13.
Honarvar M, Allahyari M. Assessment of gestational age based on ultrasonic femur length in fetus. Acts Med Iran 1999;37:134-8.  Back to cited text no. 13
    
14.
Gupta DP, Saxena DK, Gupta HP, Zeeshan Z, Gupta RP. Fetal femur length in assessment of gestational age in third trimester in women of Northern India (Lucknow, UP) and a comparative study with Western and other Asian countries. Indian J Clin Pract 2013;24:372-5.  Back to cited text no. 14
    


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Materials and Me...
Observation and ...
Discussion
Conclusion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed1745    
    Printed94    
    Emailed0    
    PDF Downloaded106    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]